Please attend the webinar (or watch the post-production video) for demonstration and additional details. As always, please contact support for additional information and let us know if you have any feedback.
New Features
-
Option to prevent placement of ‘structural’ openings
-
There is a new checkbox under the Bays framing rules group called ‘No Structural Doors’
-
If’ No Structural Doors’ is checked ON, then a door (or window) that will not fit between posts will not be placed in the bay (the cursor will show a ‘Cannot Place’ symbol)
-
-
-
Options for girts at corner posts
-
There is a new question under the ‘Wall Girt Framing’ group called ‘Girt Corner’ with the following options:
-
Both Long: both girts will run long at the corner (default answer and current behavior)
-
Both Short: both girts will be held back to the outside of the post
-
Eave Short: the girt on the eave side will be held back at the corner and the girt on gable side will run long
-
Gable Short: the girt on the gable side will be held back at the corner and the girt on eave side will run long
-
-
Truss Carrier, Skirt Board and Wainscot Girts will follow this setting
-
-
Tax option for job truss adjustments
-
In the Job Review, there is a new ‘Taxable’ selection option to apply to truss adjustments or when adding a truss from a job
-
-
Double rafters on posts
-
There is now a ‘Double Rafter’ framing rule check box in the ‘Rafter Framing’ section to place rafters on each side of posts
-
Double Rafter can be set independently for attached buildings
-
-
Minimum password length increased from 6 to 8
-
It will NOT require a change to current passwords, but a new password will need to be at least 8 characters
-
-
Bug-Rafter Layouts are off when using Custom Bay Spacing and Overhangs FIXED
-
Bug-Porch condition on eave wall causes the trusses on that eave wall to not sit on top of the posts has been FIXED
-
Bug-No sheathing on the building causes the Cross sections output not to work has been FIXED
-
Bug-Window location rounding inconsistency causes structural window has been FIXED
-
Bug-With single and top girt truss carriers, a gable style roof attached to a gable wall of a main building at the corner adds an extra post has been FIXED